Broadcom Limited Avenger MR 8.16 Storcli2
*******************************************


======================
Supported Controllers
==================

Avenger 9600-16e
Avenger 9600-8i8e
Avenger 9600-16i
Avenger 9600-24i
Avenger 9600w-16e
Avenger 9620-16i
Avenger 9660-16i
Avenger 9670W-16i
Avenger 9670-24i

Component:
==========
Release Date:   2026-02-10


Version Numbers:	
================			
Current Version:   008.0016.0000.0011
Previous Version:  008.0015.0000.0010

Bug Fixes/Enhancements:  
=======================
DCSG01942994 Displaying complete Controller properties in storcli2
DCSG02006306 Volume creation command fails to display the message when Volume create is requested from a slot where drive is missing
DCSG01942754 Deliver MPI changes over prior release
DCSG01975083 Storcli shows incorrect values for volume "NVMEdefaults", "SSDdefaults" and "HDDdefaults".
DCSG01975519 (Port Of Defect DCSG01975479) Storcli command outputs doesn't comply with customer branding
DCSG01969300 Smart Self test info Progress field  for HDD(SAS) not shown ,shown for NVME/SATA
DCSG01974056 PQC Algorithm name is displayed even for empty slots
DCSG01941806 [VMware] Broadcom NVMe Controller Discovery
DCSG01975071 Storcli show/set hostatajbodsecurity fails with syntax error.
DCSG01983551 "Volume info" is showing "SCSI Status:" failure when background operations on the volume is going.
DCSG01967157 DCMD implementation to switch the I2C bus discovery mode
DCSG01972966 Storcli fails to list allowed Drives for mapping
DCSG01938576 Debug ability improvements
DCSG02010351 Transfomation is listed as online capacity in controller events for operation type
DCSG02006677 Instance Validation Failed on some of the schemas.
DCSG01972538 (Port Of Defect DCSG01961835) Incorrect drive status response received when issuing drive rebuild status in IT config
DCSG01972223 Multiple error messages during POH on drives.
DCSG01967312 Online Capacity Expansion Limitation: No Foreign Config Import Allowed Until Completion
DCSG01972208 Set patrol read includevd command has debug prints
DCSG02001048 show ssddefaults displays Cache Bypass IOSize as 0 instead of 64K
DCSG01984088 Drive AU Size displayed as 0Kib, where as Drive size shown as "-"
DCSG02010758 (Port Of Defect DCSG02010745) Json Schema for number and string types
DCSG01970168 No proper output while setting CONSISTENCYCHECK execfrequency for weeks/days.
DCSG01977300 StorCLI2.exe /c0 /pf0 add map with all volumes need to return correct error message
DCSG01999659 storcli2 json output displays overall status "controller" property sometimes returns an int (e.g., 4), and other times a string
DCSG01975524 During drive replace operation Storcli accepts Incorrect "reconfig" namespace parameter.
DCSG01960507 Utility import message during Provisioning process
DCSG01928941 provide method for removal of a virtualdisk from the exclusion list from patrol read
DCSG01977309 Update IOP_LOGINFO_CODE for download failure case
DCSG01960460 CNSA updates for common components
DCSG01968617 (Port Of Defect DCSG01964195) Incorrect message while setting FirstdeviceID.
DCSG01968250 defaults strip size listed as 65KB instead of 64KB
DCSG01970207 Intermittently observing StorCLI crash on querying the controller
DCSG01962307 (Port Of Defect DCSG01961880) "show events latest" output is not showing the first event data after factory repurpose.
DCSG01969482 Implement the Enhanced string in CLI prereview configuration for the non importable foreign reason.
DCSG02001007 Updating the IOC loginfo for new IOP_LOGINFO_CODE_CIDL_ACT_VALIDATE_TROMBONE_ENCL_SUPPORT
DCSG01964709 Volume is displayed as virtual drive in ASO for CLI
DCSG01976788 Fixing Static analysis tool issues
DCSG01975340 R60 with preserved cache is reporting incorrect Volume size with CLI show preservedcache command
DCSG01980295 PF add/remove command failure output doesn't comply with customer branding
DCSG01999341 Numerous repetitive prints are seen 700+ for each DCMD when Degraded
DCSG01954171 (Port Of Defect DCSG01954118) Mismatch between the locked drive between foreign output with drive detailed output
DCSG02000613 Mode 5 (parallel) Drive image fails with failure The MPI3 SCSI IO request validation
DCSG01935148 Security Audit Improvements
DCSG01987765 Foreign Drives that are not importable are shown as importable in EVP
DCSG01968831 Show function profile is listing confused column name for MaxQueues/Vector
DCSG01990876 Updated the controller health to critical when Volume is non optimal
DCSG01969355 (Port Of Defect DCSG01969203) Storcli2 crashes on controller show all" command When any volume progress is ongoing
DCSG01941801 [Windows] Broadcom NVMe and Mixed mode(MPI+NVMe) Controller Discovery
DCSG01984300 Enable support for the Enclosure with MR8 controller- H965e
DCSG01966406 (Port Of Defect DCSG01965125) Storcli show all command output doesn't comply with customer branding
DCSG02014854 Storcli2 reports incorrect output format for PCI Slot Number in v008.0016.0000.0005
DCSG02004879 common-schema.json not in JSON format.
DCSG01984410 Error msg Description is not shown properly when there SMART & Non-SMART enabled drives
DCSG02007741 Update IOC LOGINFO for the component image download
DCSG01969310 (Port Of Defect DCSG01969124) Storcli 'Volume show, 'Expand' command output doesn't comply customer terminology
DCSG01990882 Discovery mode setting with "auto" sending the value wrongly
DCSG01996797 (Port Of Defect DCSG01996792) Update property "Security QR Enabled" as per latest MPI changes  to "Security QR Secured"
DCSG01949846 Add the NVMe drive smart info with the property "Self-test status" if operation is ongoing
DCSG01974168 Storcli fails to set firstdeviceid to default value.
DCSG01969502 (Port Of Defect DCSG01969183) Failed to set 'firstdeviceid' on PFs for volumes
DCSG01975001 Openssl 3.5.1 migration
DCSG02005911 Storcli2 returns extra prints mesg when import the certificate on the slot
DCSG01968604 Displaying the PDDisk count from CLI when lower layers is not populating it